首页 | 本学科首页   官方微博 | 高级检索  
     

优化控制应用于制冷机房的节能性研究
引用本文:黄翔,刘月琴.优化控制应用于制冷机房的节能性研究[J].暖通空调,2012,42(4):68-71,20.
作者姓名:黄翔  刘月琴
作者单位:杭州国电能源环境设计研究院
摘    要:以冰蓄冷系统为研究对象,根据实测数据,分析了不同运行策略下的节能效果.测试结果表明,优化控制系统较常规控制系统减少了14.6%的电费.

关 键 词:冰蓄冷空调  制冷机房  优化控制  节能率

Energy saving research of optimal control applied to refrigerating plant rooms
Huang Xiang , Liu Yueqin.Energy saving research of optimal control applied to refrigerating plant rooms[J].Journal Heating Ventilating and Airconditioning,2012,42(4):68-71,20.
Authors:Huang Xiang  Liu Yueqin
Affiliation:Huang Xiang and Liu Yueqin Hangzhou State Power Energy Environment Design and Research Co.,Ltd.,Hangzhou,China
Abstract:Taking ice storage system as a study object and based on measured data,analyses the energy saving effect in different operating strategy.The test results show that adopting the optimal control system reduces the cost of electric power consumed by 14.6 percent compared to the conventional control system.
Keywords:ice storage system  refrigerating station  optimizing control  energy saving rate
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号