Thermal behaviour of autoclaved aerated concrete exposed to fire
Affiliation:1. School of Civil Engineering, Hefei University of Technology, Anhui Province 230009, China;2. Anhui Civil Engineering Structures and Materials Laboratory, Anhui Province 230009, China;1. Department of Civil, Environmental, Land Management Engineering and Architecture, University of Parma, P.co Area delle Scienze 181/A, 43124 Parma, Italy;2. Department of Civil and Environmental Engineering, Politecnico di Milano, Piazza L. Da Vinci 32, 20133 Milano, Italy
Abstract:The reaction to fire of autoclaved aerated concrete (AAC) has been investigated at multiple dimensional scales. Changes in the chemical composition were detected and analysed by means of thermal analysis methods. Then, the thermal conductivity after different heat treatments was measured at different temperatures ranging from 120 °C to 720 °C. Finally, the evolution of temperature in an AAC wall exposed to the standard fire of ISO 834 has been monitored by built-in temperature sensors. The results hereof were used as input for a transient and non-linear numerical model which has been set up to predict temperatures at different depths of the wall. Measured and calculated results have been compared and discussed.
Keywords:Autoclaved aerated concrete  Fire  Thermal analysis  Thermal conductivity  Dehydration  Effective heat capacity
本文献已被 ScienceDirect 等数据库收录!