首页 | 本学科首页   官方微博 | 高级检索  
     

火焰原子吸收光谱法间接测定氧化锌烟尘中氯
引用本文:王亚健,张利波,彭金辉,孙成余,巨少华,张旭. 火焰原子吸收光谱法间接测定氧化锌烟尘中氯[J]. 冶金分析, 2013, 33(7): 41-44
作者姓名:王亚健  张利波  彭金辉  孙成余  巨少华  张旭
作者单位:1.云南省特种冶金实验室,云南昆明 650093;2. 非常规冶金教育部重点实验室,云南昆明 650093;3.昆明理工大学冶金与能源工程学院,云南昆明 650093;4. 云南驰宏锌锗股份有限公司,云南曲靖 655011
基金项目:国家自然科学基金资助项目(No.51104073);云南省中青年学术技术带头人后备人才资助项目(No.2012HB008)
摘    要:以稀硝酸溶解样品,然后向样品溶液中加入过量Ag+标准溶液,溶液中的微量Cl-会与定量的Ag+形成氯化银胶体,加热煮沸溶液使氯化银胶体迅速凝聚并完全沉淀,采用火焰原子吸收光谱法测定滤液中剩余的Ag+量,通过换算间接得出氧化锌烟尘中的氯含量。讨论了共存离子的干扰、试样溶解条件、沉淀反应时间和测定介质,确定了最佳实验条件。采用实验方法测定烟化炉氧化锌烟尘和回转窑氧化锌烟尘中氯的含量,测得结果与氯化银比浊法基本一致,相对标准偏差(n=5)为0.65%~0.89%,回收率为99%~101%。

关 键 词:火焰原子吸收光谱法  氧化锌烟尘  间接测定    
收稿时间:2012-09-12

Indirect determination of chlorine in zinc oxide dust by flame atomic absorption spectrometry
WANG Ya-jian,ZHANG Li-bo,PENG Jin-hui,SUN Cheng-yu,JU Shao-hua,ZHANG Xu. Indirect determination of chlorine in zinc oxide dust by flame atomic absorption spectrometry[J]. Metallurgical Analysis, 2013, 33(7): 41-44
Authors:WANG Ya-jian  ZHANG Li-bo  PENG Jin-hui  SUN Cheng-yu  JU Shao-hua  ZHANG Xu
Affiliation:1. Yunnan Provincial Key Laboratory of Intensification Metallurgy, Kunming 650093, China;2. Key Laboratory of Unconventional Metallurgy, Ministry of Education, Kunming 650093, China;3. Faculty of Metallurgy and Energy Engineering, Kunming University of Science and Technology, Kunming 650093, China; 4. Yunnan Chihong Zn & Ge Co., Ltd., Qujing 655011, China
Abstract:The sample was dissolved in diluted nitric acid. Then, excessive Ag+ standard solution was added into the sample solution. Trace Cl- in sample solution would quantitatively reacted with Ag+ to form silver chloride colloid. The solution was heated and boiled to agglutinate rapidly and completely precipitate silver chloride colloid. The residual Ag+ content in filtrate was determined by flame atomic absorption spectrometry. Then, the content of chlorine in zinc oxide dust could be indirectly obtained. The interference of coexisting ions, the dissolution conditions of sample, the reaction time of precipitation and determination medium were discussed to obtain the optimal experimental conditions. The proposed method was applied to the determination of chlorine content in zinc oxide dust of fuming furnace and rotary kiln. The results were basically consistent with those obtained by silver chloride turbidimetry. The relative standard deviations (RSD, n=5) were 0.65%-0.89%. The recoveries were between 99% and 101%.
Keywords:flame atomic absorption spectrometry  zinc oxide dust  indirect determination  chlorine  
本文献已被 CNKI 等数据库收录!
点击此处可从《冶金分析》浏览原始摘要信息
点击此处可从《冶金分析》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号