摘    要:作为地区枢纽变电站,500kV变电站的主接线形式对电网的可靠性和经济性有至关重要的影响.在分析了3/2断路器接线的特点的基础上,对其可靠性进行研究,构建了主接线状态转换模型,并从工程造价上与500kV典型的双母线分段带旁路母线接线进行比较.

关 键 词:500 kV变电站  主接线  3/2断路器接线  比较

Analysis of the Main Connection In 500 kV Substation
WANG Dong. Analysis of the Main Connection In 500 kV Substation[J]. Journal of Electric Power, 2011, 26(1): 54-56
Authors:WANG Dong
Affiliation:WANG Dong(Shaoxing Electric Power Bureau,Shaoxing 312000,China)
Abstract:As a regional hub substation,the form of main connection in 500kV substation has a crucial impact in grid reliability and economy.On basis of the 3/2 breaker connection,its reliability is analyzed.The state switching model is set up and compared with double bus bar bypass bus connection from project cost.