摘    要:总降压变电站变压器容量及台数的选择原则一是满足负荷类型对供电的要求,即台数的确定,二是满足经济性要求,即容量的确定。本文通过不同方案的对比,介绍了某工程选择变压器容量及台数的方案确定过程。

关 键 词:变压器  负载率  有功功率  无功功率  供电方式

Selection of Transformer Capacity and Unit Quantity of General Step-down Transformer Substation
LIN Ping.Selection of Transformer Capacity and Unit Quantity of General Step-down Transformer Substation[J].Energy Saving Of Non-Ferrous Metallurgy,2010,26(2):31-33.
Authors:LIN Ping
Abstract:The principles for selecting transformer capacity and unit quantity of general step-down transformer substation are firstly to determine the unit quantity which shall meet the requirements for load type and power supply,then secondly to determine the capacity which shall meet the requirements for economical efficiency.This text,through comparison of different solutions,introduces the procedure for a project to determine the solution during selecting transformer capacity and unit quantity.