首页 | 本学科首页   官方微博 | 高级检索  
     


Tool for inspecting faults from incorrectly cleaved fiber ends and contaminated optical fiber connector end surfaces
Authors:Mitsuru Kihara  Masaru Okada  Makoto Hosoda  Tomoyuki Iwata  Yuichi Yajima  Masanobu Toyonaga
Affiliation:Technical Assistance and Support Center, Nippon Telegraph and Telephone East Corporation, 1-2-5 Kamata-honcho, Otaku, Tokyo 144-0053, Japan
Abstract:We investigated and analyzed faults in field installable connection due to incorrectly cleaved fiber ends and manufactured physical contact (PC)-type connectors with contaminated end surfaces in optical access fiber networks. The insertion and return losses of fiber connections using incorrectly cleaved fiber ends might be at worst more than 40 dB and less than 30 dB, respectively. With PC-type connectors whose end surfaces are contaminated, the insertion and return losses might be at worst 8.7 and 27 dB, respectively. We developed an inspection tool for cleaved fiber ends and connector end surfaces as a countermeasure. The proposed tool has a simple structure and does not require focal adjustment. It can be used to inspect and clearly determine whether a fiber has been cleaved correctly and whether there is contamination or scratches on the connector end surfaces. The tool requires a slight increase of 11% in operation time compared to conventional fiber end preparation and assembly procedures. The proposed tool provides a simple and cost-effective way to inspect cleaved fiber ends and connector end surfaces and is suitable for field use.
Keywords:
本文献已被 ScienceDirect 等数据库收录!