首页 | 本学科首页   官方微博 | 高级检索  
     


Wear and creep of highly crosslinked polyethylene against cobalt chrome and ceramic femoral heads
Authors:Galvin A L  Jennings L M  Tipper J L  Ingham E  Fisher J
Affiliation:Institute of Medical and Biological Engineering, University of Leeds, Leeds, UK. a.l.galvin@leeds.ac.uk
Abstract:The wear and creep characteristics of highly crosslinked ultrahigh-molecular-weight polyethylene (UHMWPE) articulating against large-diameter (36mm) ceramic and cobalt chrome femoral heads have been investigated in a physiological anatomical hip joint simulator for 10 million cycles. The crosslinked UHMWPE/ceramic combination showed higher volume deformation due to creep plus wear during the first 2 million cycles, and a steady-state wear rate 40 per cent lower than that of the crosslinked UHMWPE/cobalt chrome combination. Wear particles were isolated and characterized from the hip simulator lubricants. The wear particles were similar in size and morphology for both head materials. The particle isolation methodology used could not detect a statistically significant difference between the particles produced by the cobalt chrome and alumina ceramic femoral heads.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号