Study of leaktightness integrity of containment wall without liner in high performance concrete under accidental conditions—I. Experimentation
Authors:M Shekarchi  G Debicki  L Granger  Y Billard
Affiliation:a Department of Civil Engineering, University of Tehran, 14155-6457 Tehran, Iran;b INSA de LYON, URGC Structures, 69621 Villeurbanne, France;c EDF/SEPTEN, Division Génie-Civil, 69628 Villeurbanne, France
Abstract:When a partially saturated concrete wall is subjected to accidental conditions (high temperature and steam water pressure, as a LOCA or more severe conditions), water vapour penetrates the containment wall until saturation level of the containment atmosphere is achieved. The rate of penetration of water vapour through concrete is progressively reduced, leading to improvement of the leaktightness integrity of the concrete wall. In this paper, experimental studies involving the measurement of temperature, moisture propagation and pore pressures in a concrete containment wall are presented. The tests have been carried out on cylindrical specimens, made of high performance concrete (HPC) and having 1.3 m thickness (same thickness as a containment wall of a nuclear power plant). A finite element analysis is used to study the heat and mass transfer through the concrete wall. The results of this numerical modelling technique are presented in the second part of this study.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号