摘    要:从600MW火电机组三分仓回转式空气预热器积灰的形成机理及对运行机组产生的危害,来讨论其积灰防止及在线处理的办法。

关 键 词:600  MW火电机组  空气预热器  积灰  防止  在线处理
文章编号:CN31-1508(2005)03-0014-03
修稿时间:2004年7月15日

The Accumulated Ash Forms Air-preheater of the 600 MW Unit of Steam Power Plant and its Management on Line
XIE Jian-shan.The Accumulated Ash Forms Air-preheater of the 600 MW Unit of Steam Power Plant and its Management on Line[J].Boiler Technology,2005,36(3):14-16.
Authors:XIE Jian-shan
Affiliation:XIE Jian-shanHuayang Electricity Limited Corporation Houshi Power Station,Zhangzhou 363105,China
Abstract:This paper focuses on the measure of preventing and dealing with the accumulated ash on line,which is from the mechanism that the accumulated ash forms in three cents rotary air-preheater of the 600 MW unit of steam power plant and the damage it do to the service unit.