摘    要:介绍了由我国开发、研制成功的50MW蒸发冷却汽轮发电机并网投入作调相机的运行情况和10年多的运行过程中所取得的运行、维护经验.结果表明,电机定子冷却采用全浸式蒸发冷却技术,具有冷却效果好、效率高、运行可靠和维修简便等优点.

关 键 词:汽轮发电机  蒸发冷却
修稿时间:2001年2月14日

Operation of 50 MW Turbo-generator with Evaporative Cooling
Fu Deping,Zhu Rongjian.Operation of 50 MW Turbo-generator with Evaporative Cooling[J].Electrical Equipment,2001,2(3):48-50.
Authors:Fu Deping  Zhu Rongjian
Affiliation:Fu Deping~1 Zhu Rongjian~2
Abstract:This paper presents the operation results of 50 MW turbo-generator with evaporative cooling running as a phase compen- sator.This generator is the first manufactured in China.Operational results show that the fully immersed stator for cooling has various advantages over conventional machines,such as excellent cooling effect,higher efficiency,reliable operation and easy maintenance. The paper also discusses failures occurred during its 10 years operation and maintenance experience.