仪器对涤纶纤维拉伸性能测试结果的影响分析
引用本文:张秀芬,徐宏英.仪器对涤纶纤维拉伸性能测试结果的影响分析[J].合成技术及应用,2002,17(2):53-55,59.
作者姓名:张秀芬  徐宏英
作者单位:仪征化纤股份有限公司涤纶一厂,江苏,仪征,211900
摘    要:过用XQ 1和YG0 0 1 A进行初生纤维EYS1 5测试对比试验分析 ,证明两种仪器EYS1 5测试值无差异 ,并从夹持器材料性能角度分析了二者用于测试涤纶短纤维成品断裂强度、断裂伸长时有差异而测试初生纤维EYS1 5时无差异的原因

关 键 词:涤纶短纤维  屈服应力  断裂强度  断裂伸长率
文章编号:1006-334X(2002)02-0053-03

Instruments effect on result of PET fiber drawability test
ZHANG Xiu-fen,XU Hong-ying.Instruments effect on result of PET fiber drawability test[J].Synthetic Technology and Application,2002,17(2):53-55,59.
Authors:ZHANG Xiu-fen  XU Hong-ying
Abstract:According to the comparative test, the paper improved that it has no difference between the result of PET original fiber EYS1.5 test by XQ 1 and by YG001 A. But when the two instruments are used for PET staple fiber breaking strength and breaking elongation test, there is some difference. The paper also analyses the reason of this phenomenon from the angle of clamp material property.