首页 | 本学科首页   官方微博 | 高级检索  
     

入射角偏差对超声波检测结果的影响
引用本文:董 斌,李新文.入射角偏差对超声波检测结果的影响[J].焊管,2017,40(11):55-57.
作者姓名:董 斌  李新文
作者单位:宝山钢铁股份有限公司钢管条钢事业部, 上海 201900
摘    要:为了提高焊管产品焊缝缺陷超声波检测的准确性,避免漏检,排除工程质量隐患,从理论上分析了入射角(K值)偏差对缺陷深度定位的影响。并通过对两个规格焊管的实际检测,验证了理论分析结果的正确性,得到了入射角(K值)偏差对缺陷深度定位的影响规律。研究结果表明,在实际工程生产中,超声波检测入射角(K值)偏差小于0.2可接受,大于0.2则必须更换探头。

关 键 词:检测  无损探伤  超声波  K值

Influence of Deviation of Incident Angle on Result of UT Testing
Dong Bin,Li Xinwen.Influence of Deviation of Incident Angle on Result of UT Testing[J].Welded Pipe and Tube,2017,40(11):55-57.
Authors:Dong Bin  Li Xinwen
Affiliation:Tube, Pipe and Bar Business Unit, Baoshan Iron& Steel Co., Ltd., Shanghai 201900, China
Abstract:In order to improve the accuracy of weld defects ultrasonic testing, avoid misjudge, eliminate potential hazards of project quality, it analyzed the influence of incident angle(K value) deviation on defect depth localization. Through practical testing of two specifications welded pipe, the accuracy of the analysis results in theory was verified, and influencing rule of incident Angle(K value) deviation on defect depth localization was obtained. According to the research results, in actual engineering production, ultrasonic testing incident Angle(K value) deviation less than 0.2 was acceptable, but if it was greater than 0.2, the probe must be changed.
Keywords:detection  nondestructive examination  ultrasonic  K value