摘    要:分析了高压电力系统对移动通信基站产生电磁影响的耦合途径,提出了地电位升限值建议和防护隔距计算方法,给出了在特定参数条件下两者间的隔距计算结果和可能采取的防护措施。

关 键 词:高压电力系统  移动通信  基站  地电位升  隔距  防护措施
修稿时间:2005-11-22

Calculation of Interval between Mobile Communication Base Station and High Voltage Power System
Ma Weimin,Niu Jiansheng. Calculation of Interval between Mobile Communication Base Station and High Voltage Power System[J]. Designing Techniques of Posts and Telecommunications, 2006, 0(1): 55-60
Authors:Ma Weimin  Niu Jiansheng
Affiliation:Ma WeiminNiu Jiansheng
Abstract:It analyses the coupling path of emergent EMI to base station by high voltage power system, presents the suggestion on ground potential rise limited value and calculation methods of protection interval, and gives the calculation results of interval under specified parameter conditions and protection measures.