Affiliation:1. Korea Research Institute of Standards and Science, 267 Gajeong-ro, Yuseong-gu, South Korea;2. National Institute of Advanced Industrial Science and Technology, National Metrology Institute of Japan, Tsukuba Central 3, Umezono 1-1-1, Tsukuba, 305-8563, Japan
Abstract:A Pitot tube is a popular device used for the measurements of flow fields. To control the accuracy of the Pitot tube coefficient, the international standard organization (ISO), the American Society for Testing and Materials (ASTM), and the Japanese Industrial Standards (JIS) issued guidelines that recommended the shape and working conditions of these devices. However, many Pitot tubes on the market do not follow these guidelines. In the present study, various types of Pitot tubes in the market were tested at the National Metrology Institute of Japan (NMIJ) to determine the effects of the geometry and flow characteristics. The results revealed certain limitations in the existing ISO and JIS standards, specifically with regard to the recommended design parameters of the AMCA Pitot tube, the reference coefficient value for the JIS Pitot tube, and the redefinition and limitation of Reynolds numbers pertaining to Pitot tube working conditions.
Keywords:Pitot static tube  Reynolds number effect  Pitot tube geometry
本文献已被 ScienceDirect 等数据库收录!