摘    要:由于短线路同杆并架双回线越来越多,如何获得其准确的参数是亟待解决的问题。提出了基于PMU的短线路同杆并架双回线参数估计新方法。基于导体之间的耦合首先推导了短线路同杆并架双回线的阻抗模型;利用PMU在线实测数据提出了相应的短线路相角矫正方法和基于最小二乘法的短线路同杆并架双回线参数估计算法。该模型完整,算法直观简单,能够准确、快速地算得短线路同杆并架双回线之间的所有自感及互感参数。算例证明了该方法的有效性和正确性。

关 键 词:电力系统  同杆并架双回线  参数辨识  PMU  最小二乘法  
收稿时间:2020-01-08
修稿时间:2020-01-31

Parameter Identification of Short Parallel Double-Circuit Lines Based on PMU Measurements
HUANG Xiaoxiao,YANG Tao,ZHENG Xiaolin,GUO Lingxu,LIN Jikeng.Parameter Identification of Short Parallel Double-Circuit Lines Based on PMU Measurements[J].Electric Power,2020,53(7):141-148.
Authors:HUANG Xiaoxiao  YANG Tao  ZHENG Xiaolin  GUO Lingxu  LIN Jikeng
Affiliation:1. Electric Power Research Institute of State Grid Tianjin Electric Power Company, Tianjin 300384, China;2. Shanghai University of Electric Power, Shanghai 200090, China;3. State Grid Tianjin Electric Power Company, Tianjin 300010, China;4. College of Electronic and Information Engineering, Tongji University, Shanghai 201804, China
Abstract:With the continuous increasing of short parallel double-circuit lines, it is an urgent problem to obtain their accurate parameters. In this paper, a new PMU-based method is proposed to estimate the parameters of short parallel double-circuit lines. Firstly, based on the coupling between conductors, the impedance model of short parallel double-circuit lines is deduced. And then, the corresponding short line phase angle correction method and the parameter estimation algorithm of short parallel double-circuit lines based on least square method are presented using the online PMU measurement data. The proposed model is complete, and the algorithm is simple and straightforward, which can accurately and quickly calculate all the parameters of short parallel double-lines. Case study has validated the effectiveness and correctness of the proposed method.
Keywords:power system  parallel double-circuit lines  parameter identification  PMU  least square method  
本文献已被 CNKI 等数据库收录!
点击此处可从《中国电力》浏览原始摘要信息
点击此处可从《中国电力》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号