首页 | 本学科首页   官方微博 | 高级检索  
     


Bolometers operated at 0.1 K and 0.2 K cooled by adiabatic demagnetization
Authors:Larry Lesyna  Thomas P. L. Roellig  Peter Kittel
Affiliation:1. Center for Space Science and Astrophysics, Stanford University, 94305, Stanford, CA
2. NASA-Ames Research Center, 94035, Moffett Field, CA
Abstract:We have constructed bolometers operating at temperatures of 0.1 K and 0.2 K cooled by adiabatic demagnetization. The electrical noise equivalent power (NEP) of the bolometers was found to be 1.8×10?16 W/Hz1/2 and 6.6×10?16 W/Hz1/2 respectively. These values are within a factor of two of the expected performance based upon bolometer theory. The thermistor material used was gallium doped single crystal germanium, for which we find a resistivity temperature dependence of the form ρ = ρo exp (AT?1/2).
Keywords:
本文献已被 SpringerLink 等数据库收录!