首页 | 本学科首页   官方微博 | 高级检索  
     


Hg+ trapped ion standard with the superconducting cavitymaser oscillator
Authors:Prestage   J.D. Tjoelker   R.L. Wang   R.T. Dick   G.J. Maleki   L.
Affiliation:Jet Propulsion Lab., California Inst. of Technol., Pasadena, CA;
Abstract:The frequency stability of an atomic standard based on 199 Hg+ ions confined in a hybrid RF/DC linear trap is described. The 40.5-GHz clock transition has been measured to be 17 mHz wide, representing a quality factor greater than 2×1012. A 160-mHz line is used to steer the output of a 5-MHz crystal oscillator to obtain a stability of 2×10-15 for 24000-s averaging times. In a separate measurement, a 37-mHz line is used to steer the output of the superconducting cavity maser oscillator to reach 1×10-15 stability at 10000 s
Keywords: