Abstract:For analyzing ejector's performance in the system, an ejector for a 10 kW polymer electrolyte membrane fuel cell (PEMFC) system was first designed, manufactured, and a 10 kW PEMFC system bench was built up. A proportional valve and PI pressure feedback control method were adopted to control the hydrogen supply and anode inlet pressure. During the test, performances between dead-ended anode (DEA) mode and ejector mode were compared. Ejector's performances in the system, i.e., volume flow recirculated ratio, difference pressure, dynamic responses of primary pressure, anode inlet pressure, and recirculated gas flow rate during the purge process and current variation condition, were investigated. The results show that pressure adjustment is accurate, continuous, and fast using the proportional valve and PI pressure feedback control method. The hydrogen consumption rate in the ejector mode can reduce from 5% to 10% compared with the rate in the DEA mode except for the stack current 5 A and 10 A conditions. For better water removal out of the anode channel in ejector mode, the maximum stack power increases from 5.11 kW (DEA mode) to 9.56 kW (ejector mode). Anode pressure surge caused by the purge valve switching enhances the ejector's recirculated performance significantly.