空分启动阶段主换热器热端温差过大的原因分析及处理
引用本文:曾周华. 空分启动阶段主换热器热端温差过大的原因分析及处理[J]. 深冷技术, 2004, 0(5): 29-30
作者姓名:曾周华
作者单位:南昌钢铁有限责任公司制氧厂,江西省南昌市罗家镇,330012
摘    要:介绍了空分设备启动阶段主换热器热端温差过大的现象和原因 ,通过计算膨胀机的最大膨胀量 ,得出膨胀量偏大是导致热端温差过大的原因

关 键 词:空分设备  热端温差  膨胀机  过冷  主换热器
文章编号:1009-9425(2004)05-0029-02
修稿时间:2004-06-08

Analyzing the excessive temperature difference at warm end of a main heat exchanger during start-up of an ASU and solutions
Zeng Zhou-hua. Analyzing the excessive temperature difference at warm end of a main heat exchanger during start-up of an ASU and solutions[J]. Cryogenic Technology, 2004, 0(5): 29-30
Authors:Zeng Zhou-hua
Abstract:The appearance and causes linking to the excessive tem perature difference at warm end of a main heat exchanger during start-up of an air separation unit are outlined.By calculating the maximum expansion capacity o f an expander,it is concluded that the higher expansion capacity can result in the e xcessive temperature difference at warm end of the exchanger.
Keywords:Air separation unit  Temperature differe nce at warm end  Expander  Subcooling  Main heat exchanger