Flow characteristics in a column agitated by blade impellers |
| |
Authors: | Chul Soo Kim Dae Ki Choe Won Kook Lee |
| |
Affiliation: | (1) Department of Chemical Engineering Korea, Advanced Institute of Science and Technology, 131 Seoul, Korea;(2) Daeduk Engineering Center, Korea Advanced Energy Research Institute, 131 Seoul, Korea |
| |
Abstract: | Flow characteristics, axial dispersion coefficients in the continuous phase, and holdup of the dispersed phase were studied
in a 4.66 cm inside diameter and 100 cm height column agitated by blade impellers.
Flow characteristics were analyzed by residence time distribution using impulse input of a tracer. The best reasonable values
of Peclet number and holding time were able to obtain by using the response surface method.
The axial dispersion coefficients in the single phase flow, and in the two-phase countercurrent flow have been correlated
within a confidence level of ±10% when impeller diameter, impeller speed and compartment height, were used as variables. The
holdup of the dispersed phase was also correlated in terms of impeller diameter and the operating variables. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|