摘    要:设计接地网时,接地电阻应满足接触电位差和跨步电位差的要求。接地网基本采用水平复合接地网。根据地质、地貌的情况,对各种降阻方案进行技术性、经济性比较,阐述目前使用较广泛的降阻方法的特点及存在的问题。选择科学合理的方案,以满足接触电位差和跨步电位差的要求,达到降阻的目的。

关 键 词:变电站  接地网  接地电阻  降阻措施

Comparison of Resistance Reduction Methods of Grounding Grid in High Soil Resistivity Area
YANG Ming-jun.Comparison of Resistance Reduction Methods of Grounding Grid in High Soil Resistivity Area[J].Guangxi Electric Power,2012(1):67-70.
Authors:YANG Ming-jun
Affiliation:YANG Ming-jun(Wuzhou Power Supply Bureau,Guangxi Power Grid,Wuzhou 543002,China)
Abstract:Grounding resistance must satisfy the demand of contact potential difference and step potential difference in the design of grounding grid.Grounding grid is commonly horizontal and composite.All kinds of resistance reduction methods are compared technically and economically according to circumstances of geology and geomorphology.Characteristics of general used resistance reduction methods and their problems are described.The scientific reasonable method is chose to satisfy the demand of contact potential difference and step potential difference and to achieve the purpose of resistance reduction.
Keywords:substation  grounding grid  grounding resistance  resistance reduction measure