Abstract:The jet bubble column consists of a conical entrance section which expands to a cylindrical column. Gas and liquid are co-currently introduced at the bottom of the column by a small diameter inlet pipe which acts like an ejector. The kinetic energy of the gas and liquid jet together with the conical geometry at the lower section of the column cause the formation and dispersion of small bubbles.

Gas-liquid mass transfer in the jet bubble column (61 cm diameter) was measured by a dynamic response technique, in which a step change was made in the gas phase oxygen concentration and the aqueous dissolved oxygen concentration response was measured at various axial and radial locations. It was found that a continuous stirred tank reactor model could be used to evaluate experimental results. The volumetric mass transfer coefficient in this type of system was found to increase with increasing gas flow rate and was about 1.5 times larger than the values obtained at similar conditions in conventional bubble columns. Preliminary measurements and calculations indicate negligible effects of liquid velocity and bed height on the mass transfer coefficient.
Keywords:Gas-liquid  Mass transfer  Jet bubble column  Muttiphase  Bubble column and interphase mass transfer