摘    要:分析了哈三电厂3号炉电除尘器存在的问题的原因,进行了振打周期正交调整试验,采用了相应的解决措施,建议设置自然清扫装置,增大极限间距,尽量选用管状芒刺线。

关 键 词:电厂 电除尘器 锅炉 除尘效率
文章编号:1002-1663(2002)03-0224-03
修稿时间:2001-10-29

Problems with Dust Removers of No. 3 Boiler at Harbin No. 3 Power Plant and Their Remedies
JIANG Qing song,CHEN Zeng ji,ZHANG Xue jun,WEI Wei. Problems with Dust Removers of No. 3 Boiler at Harbin No. 3 Power Plant and Their Remedies[J]. Heilongjiang Electric Power, 2002, 24(3): 224-226
Authors:JIANG Qing song  CHEN Zeng ji  ZHANG Xue jun  WEI Wei
Abstract:Analyses the causes for the problems with the electric dust removers of No.3 boiler at Harbin No.3 Power Plant,describes the orthogonal adjustment of vibration cycle, and suggests such remedies as installation of auctomatic cleaners, increase of gap between electrode plates, and use of much tubular prickled wires as possible.