首页 | 本学科首页   官方微博 | 高级检索  
     

淮北电厂5号炉预热器换型改造后的节能减排效果分析
引用本文:戚明浩 王凤豪. 淮北电厂5号炉预热器换型改造后的节能减排效果分析[J]. 安徽电力, 2007, 24(3): 75-77
作者姓名:戚明浩 王凤豪
作者单位:大唐淮北发电厂,大唐淮北发电厂 安徽 淮北 235000,安徽 淮北 235000
摘    要:为节能减排,大唐淮北发电厂对漏风大、换热效率低的5号炉老旧预热器进行了换型改造。通过对改造后风机电耗、锅炉效率和粉烟尘排放等多项运行数据分析,改造后预热器漏风率大幅度降低,风机电耗下降;换热效率增强,热风温度提高,锅炉效率提高,粉尘及其它污染物排放减少,达到了预计的技术改造效果。

关 键 词:预热器漏风  换型改造  运行经济性  节能减排  效果分析
收稿时间:2007-08-01

Analysis of effect for energy-saving and emission reduction after No.5 boiler preheater be reconstructed
Abstract:For energy-saving and emission reduction, Datang Huaibei Power Plant changed the type of NO.5 old preheater furnace which had air leakage and low heat transfer efficiency. Right after the analysis of adoption of wind electromechanical consumption, boiler efficiency and flour dust emissions and many other operational data, modified preheater significantly reduce air leakage rate, wind electromechanical consumption declined; enhance the efficiency of heat transfer, hot air temperature has increased boiler efficiency, dust and other pollutants emission reductions achieved expected the effect of technological transformation.
Keywords:preheater air-leakage   renovation   operation economy   energy-saving and emission reduction   effectiveness analysis
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏