双曲线型冷却塔爆破拆除切口参数研究
引用本文:吴剑锋.双曲线型冷却塔爆破拆除切口参数研究[J].爆破,2009,26(1).
作者姓名:吴剑锋
作者单位:武汉铁四院控制爆破技术有限公司,武汉,430063
摘    要:双曲线结构冷却塔上窄下宽,重心较低,爆破缺口形成后易产生后坐或坐而不倒现象.在阐述冷却塔爆破拆除失稳机理的基础上,结合一工程实例,探讨了爆破切口弧长和切口高度的设计,并对冷却塔爆破拆除过程中的下坐及预防措施提出了自己的看法.

关 键 词:冷却塔  爆破拆除  后坐  切口参数

Research on Cut Parameters for Blasting Demolition of Hyperbolic Cooling Tower
WU Jian-feng.Research on Cut Parameters for Blasting Demolition of Hyperbolic Cooling Tower[J].Blasting,2009,26(1).
Authors:WU Jian-feng
Affiliation:Controlled Blasting Technology Co Ltd;The Forth Survey and Design Institute of Railway Ministry;Wuhan 430063;China
Abstract:The hyperbolic cooling tower is narrow at top but broad at bottom with lower center of gravity so that recoiling and squatting without collapse often occured in blasting demolition.Combined with an engineering example,the design on the length and height of blasting cut was discussed based on the mechanism of cooling tower demolition instability in this article and also the views on recoil and the preventive measure was given out.
Keywords:cooling tower  blasting demolition  recoil  cut parameters  