加氢反应器压降增长过快的原因和措施
引用本文:王秋灵,程豪奇.加氢反应器压降增长过快的原因和措施[J].石油化工安全环保技术,2004,20(4):41-43.
作者姓名:王秋灵  程豪奇
作者单位:中国石化洛阳分公司 471012 (王秋灵),中国石化洛阳分公司 471012(程豪奇)
摘    要:针对直馏柴油加氢精制反应器床层压降过快增长的原因进行了分析,采取了增设原料过滤器和聚结器、反应器撇头清除杂质、换热器吹扫等措施,实践证明,这些方法切实可行,效果较好。并针对现况提出了存在问题和建议。

关 键 词:加氢反应器  压降  原因  措施

Measure and Cause of Too Fast Increase of Pressure Drop Across Hydrogenation Reactor
Wang Qiuling Cheng Haoqi.Measure and Cause of Too Fast Increase of Pressure Drop Across Hydrogenation Reactor[J].Petrochemical Safety and Environmental Protection Technology,2004,20(4):41-43.
Authors:Wang Qiuling Cheng Haoqi
Abstract:The causes of too fast increase of the pressure drop across the hydrofining reactor in Luoyang Company were presented. Measures to deal with this problem, such as the addition of feedstock filter and coalescer, the adoption of top skimming of the catalyst bed to remove contaminants in the reactor as well as purging heat exchanger etc. were presented. The practice has proved these measures are practical and results satisfactory. And the problem were presented according to the situation.
Keywords:Hydrogenation reactor  Pressure drop  Cause  Measure