基于高比例可再生能源的废矿抽蓄电站优化配置研究
作者姓名:滕松  刘毅  钟睿  张敬  梁睿
作者单位:国网徐州供电公司,江苏煤矿电气与自动化工程实验室,江苏煤矿电气与自动化工程实验室,江苏省电力公司检修分公司,江苏煤矿电气与自动化工程实验室
基金项目:1.国家重点研发计划“矿山安全产物联网关键技术与装备研发”(2017YFC0804400);2.国家电网公司科技项目资助(J2018078);3.国家电网公司科技项目资助(J2018036);4.国家电网江苏省电力有限公司科技项目(J2019117);5. 江苏省“六大人才高峰”项目(XNY-046)
摘    要:发展以风光能源为代表的绿色清洁能源已经成为大势所趋,与此同时,随着国家深入推进煤炭去产能进程,大量煤矿被废弃,废矿治理研究颇受重视。为此,首先设计了废矿抽蓄电站的基本结构,对废矿抽蓄电站的运行功率和不同运行工况进行数学建模。在此基础上,以降低废矿抽蓄电站投资成本、矿区配电网系统运维成本及弃风弃光和负荷缺电的惩罚成本为目标,构建了废矿抽蓄电站的优化配置模型。通过混合粒子群和模拟退火算法,对优化配置模型进行求解。基于改进的IEEE 14节点配电网系统建立测试案例,对比不同场景下废矿抽蓄装机容量和接入节点对目标函数的影响,对优化配置模型和算法的有效性进行了分析和验证,确定废矿抽蓄电站的装机容量和选址等相关参数。

关 键 词:废矿抽蓄电站    矿区配电网    优化配置    风光能源
收稿时间:2019/8/1 0:00:00
修稿时间:2019/10/22 0:00:00

Optimal configuration of abandoned mine pumped storage power station based on high proportion of renewable energy
Authors:TENG Song  LIU Yi  ZHONG Rui  ZHANG Jing  LIANG Rui
Affiliation:State Grid Xuzhou Power Supply Company,School of Electrical and Power Engineering,China University of Mining and Technology,School of Electrical and Power Engineering,China University of Mining and Technology,State Grid Jiangsu Maintenance Company,School of Electrical and Power Engineering,China University of Mining and Technology
Abstract:The development of green and clean energy represented by wind and photovoltaic energy has become the trend of the times.At the same time,as the country deepens the process of coal de-capacity,a large number of coal mines have been abandoned,and research on waste mine management has received much attention.To this end, this paper firstly designed the basic structure of the abandoned mine pumped storage station,and mathematically modeled the operating power and different operating conditions of the abandoned mine pumped storage station. On this basis,aiming at reducing the investment cost of abandoned mine pumped storage station,the operation and maintenance cost of mine distribution network system,and the penalty cost of abandoned wind and photovoltaic shortage and load shortage,the optimal configuration model of abandoned mine pumped storage station was constructed.The optimized configuration model is solved by a hybrid particle swarm and a simulated annealing algorithm.Based on the improved IEEE 14-node distribution network system, the test cases are established.The effects of the installed capacity of the waste mine and the access node on the objective function in different scenarios are compared.The effectiveness of the optimized configuration model and algorithm is analyzed and verified.Relevant parameters such as installed capacity and site selection of abandoned mine pumped storage station.#$NLKeywords: abandoned mine pumped storage station; mine distribution network system; optimized configuration; wind and photovoltaic energy
Keywords:abandoned mine pumped storage station  mine distribution network system  optimized configuration  wind and pho-tovoltaic energy