摘    要:以某可再生能源建筑应用示范项目为例,介绍土壤源热泵系统能效测评的基本内容与方法,并对该项目土壤源热泵系统冬季运行工况进行能效检测。检测结果表明,该系统冬季COPSH达到3.1,节能率达到22.3%。

关 键 词:土壤源热泵  能效测评  可再生能源

Performance detection and energy-saving analysis of ground-source heat pump system for one villa
Gong Wei,Zhu Jian,Shen Nianjun.Performance detection and energy-saving analysis of ground-source heat pump system for one villa[J].Refrigeration and Air-conditioning,2013(3):72-75.
Authors:Gong Wei  Zhu Jian  Shen Nianjun
Affiliation:1Hefei University of Technology) 2) (Anhui Building Scientific Research and Design Institute)
Abstract:Taking a demonstration project of renewable energy buildings as example, the basic ingredients and methods of the energy efficiency evaluation on ground-source heat pump system is introduced. The energy efficiency detction of ground source heat pump system for this project is done. The results show that the COPSH of this system in winter is up to 3.1 and the energy-saving rate is up to 22.3%.
Keywords:ground-source heat pump  energy efficiency evaluation  renewable energy