首页 | 本学科首页   官方微博 | 高级检索  
     

冷轧带肋钢筋焊接网混凝土板抗弯性能试验
引用本文:郑文忠,吕雪源,王英,谷勇,杜江月.冷轧带肋钢筋焊接网混凝土板抗弯性能试验[J].哈尔滨工业大学学报,2016,48(6):75-80.
作者姓名:郑文忠  吕雪源  王英  谷勇  杜江月
作者单位:结构工程灾变与控制教育部重点实验室哈尔滨工业大学,150090 哈尔滨,结构工程灾变与控制教育部重点实验室哈尔滨工业大学,150090 哈尔滨,结构工程灾变与控制教育部重点实验室哈尔滨工业大学,150090 哈尔滨,结构工程灾变与控制教育部重点实验室哈尔滨工业大学,150090 哈尔滨,结构工程灾变与控制教育部重点实验室哈尔滨工业大学,150090 哈尔滨
基金项目:《钢筋焊接网混凝土结构技术规程》(JGJ114-2003)修订基础研究课题;国家教育部长江学者奖励计划(2009-37);哈尔滨工业大学"985工程"优秀科技创新团队建设项目(2011);黑龙江省自然科学基金(E200916).
摘    要:为研究冷轧带肋钢筋焊接网混凝土板的抗弯性能,通过拉伸试验,获得了CRB600H与CRB550冷轧带肋钢筋的力学性能指标;进行了32块冷轧带肋钢筋焊接网混凝土板的受弯性能试验,测定了试验板的开裂弯矩、裂缝分布情况、变形发展规律和正截面承载力.研究结果表明:焊点未对CRB600H与CRB550冷轧带肋钢筋的力学性能产生影响;横向钢筋对试验板的开裂弯矩、裂缝间距和裂缝宽度无明显影响.建立了这类板的短期刚度计算公式,与普通混凝土板相比,这类板的抗弯刚度高约10%.根据配置CRB600H和CRB550钢筋网试验板的破坏模式,提出了这两种板正截面承载力的计算方法.

关 键 词:CRB600H钢筋  CRB550钢筋  焊接钢筋网  承载力  刚度  裂缝
收稿时间:2015/1/15 0:00:00

Flexural behavior of slabs reinforced with cold-rolled ribbed welded steel fabric
Affiliation:Key Lab of Structures Dynamic Behavior and Control Harbin Institute of Technology,Ministry of Education, 150090 Harbin, China,Key Lab of Structures Dynamic Behavior and Control Harbin Institute of Technology,Ministry of Education, 150090 Harbin, China,Key Lab of Structures Dynamic Behavior and Control Harbin Institute of Technology,Ministry of Education, 150090 Harbin, China,Key Lab of Structures Dynamic Behavior and Control Harbin Institute of Technology,Ministry of Education, 150090 Harbin, China and Key Lab of Structures Dynamic Behavior and Control Harbin Institute of Technology,Ministry of Education, 150090 Harbin, China
Abstract:The mechanical property indexes of 600 MPa and 550 MPa cold-rolled ribbed steel wires were determined through tensile test, and the cracking moment, crack distribution, deflection under different loads and normal section bearing capacity were studied through 32 slabs reinforced with cold-rolled ribbed welded steel fabric to investigate the flexural behavior of slabs reinforced with cold-rolled ribbed welded steel fabric. The results showed that solder joints had no influence on the mechanical properties of 600 MPa and 550 MPa cold-rolled ribbed steel wires. Transverse reinforcements in fabric had little effect on the cracking moment, crack spacing and crack width of this type of slabs. The short-term flexural rigidity equations were established, the flexural rigidity of this type of slabs was 10% greater than ordinary concrete slabs. Based on the failure mode of slabs reinforced with 600 MPa and 550 MPa cold-rolled ribbed steel wires, the calculation method of normal section bearing capacity was proposed.
Keywords:CRB600H  CRB550  welded steel fabric  normal section bearing capacity  stiffness  crack
本文献已被 CNKI 等数据库收录!
点击此处可从《哈尔滨工业大学学报》浏览原始摘要信息
点击此处可从《哈尔滨工业大学学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号