首页 | 本学科首页   官方微博 | 高级检索  
     

常压塔条阀塔盘开裂分析
引用本文:黄靖国,刘小辉,廖景娱. 常压塔条阀塔盘开裂分析[J]. 炼油技术与工程, 2002, 32(9): 29-32
作者姓名:黄靖国  刘小辉  廖景娱
作者单位:1. 中国石油化工股份有限公司茂名分公司,广东省,茂名市,525011
2. 华南理工大学,广东省,广州市,510641
摘    要:对开裂的条形浮阀塔盘的综合分析。结果表明 ,H2 S与HCl同时存在的电化学体系对 30 0系列不锈钢将会产生协同效应的严重腐蚀 ,引起腐蚀的主要杂质的是HCl,而H2 S则加速了腐蚀

关 键 词:常减压蒸馏装置  常压蒸馏塔  塔盘  应力腐蚀开裂  奥氏体不锈钢
修稿时间:2002-04-10

ANALYSIS OF RECTANGULAR FLOAT VALVE TRAY CRACKING IN ATMOSPHERIC DISTILLATION TOWER
Huang Jingguo,Liu Xiaohui Maoming Company/China Petrochemical Corporation. ANALYSIS OF RECTANGULAR FLOAT VALVE TRAY CRACKING IN ATMOSPHERIC DISTILLATION TOWER[J]. Petroleum Refinery Engineering, 2002, 32(9): 29-32
Authors:Huang Jingguo  Liu Xiaohui Maoming Company/China Petrochemical Corporation
Abstract:The cracked rectangular float valve tray has been analyzed and the result shows that H 2S and HCl existing in the electrochemistry system simultaneously have corroded 300 series stainless steel seriously. The corrosion was caused by HCl, and it was accelerated by H 2S.
Keywords:atmospheric and vacuum distillation unit   atmospheric distillation tower   tray   stress corrosion cracking   austenitic stainless steel  