首页 | 本学科首页   官方微博 | 高级检索  
     

Characterization of CdMnTe radiation detectors using current and charge transients
作者姓名:R. Rafiei  M. I. Reinhar  A. Sarbutt  S. Ux  D. Boardman  G. C. Watt  E. Belas  K. Kim  A. E. Bolotnikov  R. B. James
作者单位:Australian Nuclear Science and Technology Organisation,Lucas Heights,NSW,2234,Australia;School of Electrical,Electronic and Computer Engineering,The University of Western Australia,Crawley,WA,6009,Australia;Faculty of Mathematics and Physics,Institute of Physics,Charles University,Ke Karlovu 5,Prague 2,CZ-12116,Czech Republic;Brookhaven National Laboratory,Upton,NY 11973,USA;Department of Radiologic Science,Korea University,Seoul,136-703,Korea
基金项目:supported in part by the Cooperative Research Centre for Biomedical Imaging Development
摘    要:Charge transport characteristics of Cd0.95Mn0.05Te:In radiation detectors have been evaluated by combining time resolved current transient measurements with time of flight charge transient measurements.The shapes of the measured current pulses have been interpreted with respect to a concentration of net positive space-charge, which has resulted in an electric field gradient across the detector bulk.From the recorded current pulses the charge collection efficiency of the detector was found to approach 100%.From the evolution of the charge collection efficiency with applied bias,the electron mobility-lifetime product ofμnτn =(8.5±0.4)×10-4 cm2/V has been estimated.The electron transit time was determined using both transient current technique and time of flight measurements in the bias range of 100-1900 V.From the dependence of drift velocity on applied electric field the electron mobility was found to beμn =(718±55) cm2/(V·s) at room temperature.

关 键 词:radiation  detector  CdMnTe  CMT  detector  fabrication  transient  current  technique  time  of  flight  technique
修稿时间:2/8/2013 12:00:00 AM

Characterization of CdMnTe radiation detectors using current and charge transients
R. Rafiei,M. I. Reinhar,A. Sarbutt,S. Ux,D. Boardman,G. C. Watt,E. Belas,K. Kim,A. E. Bolotnikov,R. B. James.Characterization of CdMnTe radiation detectors using current and charge transients[J].Chinese Journal of Semiconductors,2013,34(7):073001-7.
Authors:R Rafiei  M I Reinhar  A Sarbutt  S Ux  D Boardman  G C Watt  E Belas  K Kim  A E Bolotnikov and R B James
Affiliation:Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW, 2234, Australia;School of Electrical, Electronic and Computer Engineering, The University of Western Australia, Crawley, WA, 6009, Australia;Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW, 2234, Australia;Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW, 2234, Australia;Faculty of Mathematics and Physics, Institute of Physics, Charles University, Ke Karlovu 5, Prague 2,CZ-121 16, Czech Republic;Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW, 2234, Australia;Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW, 2234, Australia;Faculty of Mathematics and Physics, Institute of Physics, Charles University, Ke Karlovu 5, Prague 2,CZ-121 16, Czech Republic;Brookhaven National Laboratory, Upton, NY 11973, USA;Department of Radiologic Science, Korea University, Seoul, 136-703, Korea;Brookhaven National Laboratory, Upton, NY 11973, USA;Brookhaven National Laboratory, Upton, NY 11973, USA
Abstract:
Keywords:radiation detector  CdMnTe  CMT  detector fabrication  transient current technique  time of flight technique
本文献已被 CNKI 等数据库收录!
点击此处可从《半导体学报》浏览原始摘要信息
点击此处可从《半导体学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号