摘    要:电器长期通电后可使触点表面劣化,具体体现为接触电阻稳定增大、无规律增大、周期性变化、瞬时变化等电接触失效形式。本文以银镍触点材料为例,试验研究了接触压力、通电时间和通电电流对接触电阻的影响,并分析了接触电阻劣化失效的物理机制。

关 键 词:触点材料  电接触  接触电阻  劣化  连续通电

Preliminary Study on the Contact Resistance Deterioration under the Continuous Load Current
ZHANG Chao,REN Wanbin.Preliminary Study on the Contact Resistance Deterioration under the Continuous Load Current[J].Electrical Engineering Materials,2021(2):24-27.
Authors:ZHANG Chao  REN Wanbin
Affiliation:(School of Electrical Engineering and Automation,Harbin Institute of Technology,Harbin 150001,China)
Abstract:The continuous load current passing through the electrical apparatus could result in the degradation of contact surface,whose embodiment are the stable increment,irregular increment,periodical variation and transient fluctuation and so on.In this paper,the effects of the contact force,loading duration and loading current on the contact resistance of the silver-nickel materials are experimentally investigated.And the possible physical mechanisms of the contact resistance deterioration is further analyzed.
Keywords:Contact materials  electrical contact  contact resistance  deterioration  continuous load current