首页 | 本学科首页   官方微博 | 高级检索  
     

基于场景构建的电压暂降特征量随机评估方法
引用本文:徐 悦,孙建军,丁 凯,李 伟,胡 畔. 基于场景构建的电压暂降特征量随机评估方法[J]. 电力系统保护与控制, 2021, 49(9): 105-112
作者姓名:徐 悦  孙建军  丁 凯  李 伟  胡 畔
作者单位:武汉大学电气与自动化学院,湖北 武汉 430072;国网湖北省电力有限公司电力科学研究院,湖北 武汉 430077
基金项目:国家电网公司科技项目资助(52153218000B);国家自然科学基金重点项目资助(51637007)
摘    要:电压暂降幅度与持续时间分布是电压暂降的主要特征量,也是敏感负荷损失预估及治理方案选择的重要依据.但现有随机评估方法往往存在计算量大、精度低等不足,使得分析得到的电压暂降特征值难以进行实际应用.针对配电网节点众多、负荷变化特征明显等特点,选择将场景法应用于电压暂降特征量随机评估中.首先通过K-medoids聚类方法进行节...

关 键 词:配电网  电压暂降  随机预测  短路计算  敏感负荷
收稿时间:2020-07-07
修稿时间:2020-10-03

Random evaluation method of voltage sag characteristics based on scenario construction
XU Yue,SUN Jianjun,DING Kai,LI Wei,HU Pan. Random evaluation method of voltage sag characteristics based on scenario construction[J]. Power System Protection and Control, 2021, 49(9): 105-112
Authors:XU Yue  SUN Jianjun  DING Kai  LI Wei  HU Pan
Affiliation:1. School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China; 2. Institute of Electric Power Science, State Grid Hubei Electric Power Co., Ltd., Wuhan 430077, China
Abstract:The distribution of voltage sag amplitude and duration is the main characteristic quantity of voltage sag, and it is also an important basis for sensitive load loss estimation and treatment scheme selection. However, the existing stochastic evaluation methods often have shortcomings of needing a lot of calculation and having low accuracy. This makes it difficult to apply the obtained characteristic value of voltage sag in practice. In view of the characteristics of distribution network with many nodes and obvious load variation, the scenario method is applied to the voltage sag characteristic evaluation. First, the K-medoids clustering method is used to classify the node types and select the typical nodes. Secondly, a multidimensional scene dimension reduction of the initial operation state of the distribution network is realized through the node weighted network equivalence, and then the short-circuit fault probability distribution curve and network impedance conversion are combined to propose a generation method of a typical voltage sag scene set. Finally, taking a distribution network structure as an example, the characteristic value of voltage sag at sensitive load points in the power supply area is calculated to verify the effectiveness and feasibility of the method.This work is supported by the Science and Technology Project of State Grid Corporation of China (No. 52153218000B) and the Key Program of National Natural Science Foundation of China (No. 51637007).
Keywords:distribution network   voltage sag   random prediction   short circuit calculation   sensitive load