摘    要:针对云南电力调度控制中心(以下简称云南省调)OPEN2000系统没有历史报文存储功能,对系统出现数据跳变因缺乏历史记录而无法进行分析的问题,云南省调建设了1套独立于OPEN2000系统的ET1100前置报文记录系统。该系统的投运,解决了OPEN2000系统历史报文存储问题,为进一步对历史数据分析提供了可能。ET1100系统与能量管理系统(energy management system,EMS)型号无关,适用于OPEN3000、DF8003、CC2000等国内主流EMS,对不具备报文存储功能进行了补充。

关 键 词:数据跳变  能量管理系统(EMS)  前置系统  报文监视系统

Establishment and Application of Independent Pre Message Monitoring System of Energy Management System for Yunnan Power Grid
CHEN Fei , FANG Bo , YOU Haoyun , YANG Tianguo.Establishment and Application of Independent Pre Message Monitoring System of Energy Management System for Yunnan Power Grid[J].Guangdong Electric Power,2012,25(10):95-98,112.
Authors:CHEN Fei  FANG Bo  YOU Haoyun  YANG Tianguo
Affiliation:1. Electric Power Dispatching and Control Center of Yunnan Electric Power, Kunming, Yunnan 650011, China; 2. Zhu- hai Yitong Electric Power Technology CO. LTD., Zhuhai, Guangdong 519080, China; 3. Dehong Power Supply Bubeau of Yunnan Power Grid Corporation, Mangshi, Yunnan 678400, China)
Abstract:According to that OPEN 2000 system of electric power dispatching and control center of Yunnan electric power (hereafter referred to as province dispatching) is not provided with function for historical message storage so that it may not carry out analysis because of data jump for lacking of historical records, province dispatching establishes a set of independent ET1100 pre message monitoring system. Operation of this system can provide historical message data for OPEN 2000 system and supply possibilities for further data analysis. This system is irrelevant to energy management system and can be suitable for domestic mainstream EMS such as OPEN 3000, DF 8003, CC 2000. Meanwhile, the system gives supplement for impor- tant functions for system which is not provided with function of message storage.