首页 | 本学科首页   官方微博 | 高级检索  
     


Response of alanine and radio-photo-luminescence dosemeters to mixed high-energy radiation fields
Authors:Vincke H  Brunner I  Floret I  Forkel-Wirth D  Fuerstner M  Mayer S  Theis C
Affiliation:CERN SC-RP 1211 Geneva 23, Switzerland.
Abstract:Alanine and Radio-Photo-Luminescence (RPL) dosemeters are passive dosemeters used to monitor absorbed dose in all kind of radiation fields. However, up to now both dosemeter types are calibrated to photon sources only. In order to study the response of RPL and alanine dosemeters to mixed high-energy particle fields like those occurring at CERN's accelerators, an irradiation campaign at the CERN-EC High-Energy Reference field Facility (CERF-field) was performed. In this facility a copper target is irradiated by hadrons with a momentum of 120 GeV/c. Dosemeters were exposed to various mixed radiation fields by placing them at various positions on the surface of the target. In addition to the experiment FLUKA Monte Carlo simulations were carried out, which provide information concerning the energy deposition at the dosemeter locations. This paper compares the measurements with the simulation results and discusses the radiation field compositions present at the various dosemeter positions on the target.
Keywords:
本文献已被 PubMed 等数据库收录!