摘    要:空分设备冷箱漏液,必须扒砂。介绍了扒砂过程中发生的冷箱鼓胀变形事故,分析了事故的原因和今后的防范措施,提出了安全扒砂的建议。

关 键 词:空分设备  漏液  扒砂  冷箱  鼓胀变形
文章编号:1009-9425(2005)03-0051-02
修稿时间:2005-01-29

Swollen distrotion of the cold box in an air separation unit and preventives
Wu Yu-kun,Zhou Jia-jian. Swollen distrotion of the cold box in an air separation unit and preventives[J]. Cryogenic Technology, 2005, 0(3): 51-52
Authors:Wu Yu-kun  Zhou Jia-jian
Affiliation:Wu Yu kun 1,Zhou Jia jian 2
Abstract:It is necessary to remove perlite when liquid leakage occurs in the cold box of an air separation unit.The paper describes the swollen distortion of the cold box during the course of removing perlite.The causes of this accident are analyzed with preventives put forward for the future.Furthermore suggestions concerning safety procedure of removing perlite from the cold box are made.
Keywords:Air separation unit(ASU)  Liquid leakage  Removal of perlite  Cold box  Swollen distortion