摘    要:揭露了在对流动中的气体工质进行温度测量时引起测量误差的各种因素,对产生误差的主要原因进行了详细分析,推算了热电偶探头的黑度及其在隔热套管内的位置对误差幅度的影响并给出了定量的关系.

关 键 词:气流  热电偶  隔热套管  测温误差
文章编号:1000-1999(2001)05-0023-05
修稿时间:2001-06-29

THE METHOD OF ERROR MINIMIZING IN TEMPERATURE MEASURING FOR GAS CURRENT
DAI Su ming. THE METHOD OF ERROR MINIMIZING IN TEMPERATURE MEASURING FOR GAS CURRENT[J]. Journal of Suzhou University(Engineering Science Edition), 2001, 21(5): 23-27
Authors:DAI Su ming
Abstract:When the temperature of gas current is measured by thermo pair,the value error between the true temperature and the measured one is caused.This paper gives out the cause of the error and shows the way,how to minimize it.By particular calculating,the relation between the error and the position of the thermo pair in the thermo screen is dedicated in detail.