Numerical analysis of high-temperature proton exchange membrane fuel cells during start-up by inlet gas heating and applied voltage
Authors:Raj Kamal Abdul Rasheed  Caizhi Zhang  Siew Hwa Chan
Affiliation:1. School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore;2. School of Automotive Engineering, State Key Laboratory of Mechanical Transmissions, Chongqing Automotive Collaborative Innovation Center, Chongqing University, Chongqing 400044, China
Abstract:This paper investigates the start-up or warm-up process of a high-temperature proton exchange membrane fuel cell (HT-PEMFC) from room temperature to a desired temperature of ~180 °C. The heating strategy considered in this study involves an initial heating of the HT-PEMFC by a process referred to as inlet gas heating to a temperature above 100 °C. After the fuel cell reaches above 100 °C, a voltage is applied, where electrochemical reaction heating is expected to contribute to the heating process. Thus, a numerical transient non-isothermal three-dimensional model is derived to mimic the start-up process. Operational parameters such as anode inlet temperature, cathode inlet temperature, applied voltage and voltage application temperature are varied and their effects on the maximum temperature in the membrane electrode assembly (MEA) and temperature difference in the MEA are studied. Firstly, the distribution of temperature along the channel length indicates an increase of temperature during gas heating and as the voltage is applied at the voltage application temperature, the temperature increases at the centre of the MEA due to exothermic reactions. The two-dimensional temperature distribution indicates a temperature difference between the centre of the MEA and the regions below the bipolar plate where the temperature is relatively lower. Considering the whole start-up process with respect to time, the temperature difference exists throughout the process. This will be the key focus in the parametric study. The parametric study indicates that the inlet gas temperatures, applied voltage and the voltage application temperature affect the maximum temperature in the MEA and most importantly, the temperature difference in the MEA. This can cause thermal stresses to build-up if the increase rate of temperature difference is excessive. Setting the applied voltage high (thus, lower current density) is necessary to reduce the increase rate of temperature difference.
Keywords:HT-PEMFC  Warm-up  Start-up  Heating strategy  Non-isothermal model
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号