摘    要:以北京市某既有电信行业通信机房为研究对象,针对北京地区的气候条件以及通信机房的空调负荷特性,基于自然冷却换热技术的基本理论与原理,对该通信机房原有的空调方式进行节能改造,在原有的单一空调系统基础上新增自然冷却换热系统。2009年秋季供冷工况运行结果表明,所提出的应用方案不但可以满足通信机房气流组织以及使用功能要求,而且节能效果显著。

关 键 词:通信机房  热管换热器  自然冷却技术  实验研究  工程应用  空调

Application research of using natural cooling technology to air-conditioning system for the telecommunication rooms
Xu Lei Chen Chao Guan Yong Zou Yan Chen Chen Jia Xuebin Huang Hongyu Hu Jiabi.Application research of using natural cooling technology to air-conditioning system for the telecommunication rooms[J].Refrigeration and Air-conditioning,2010(5):85-89.
Authors:Xu Lei Chen Chao Guan Yong Zou Yan Chen Chen Jia Xuebin Huang Hongyu Hu Jiabi
Affiliation:Xu Lei Chen Chao Guan Yong Zou Yan Chen Chen Jia Xuebin Huang Hongyu Hu Jiabi(Beijing University of Technology;China Railway Construction Group Co.,Ltd.)
Abstract:According to the weather conditions in Beijing and the air-conditioning load characteristics for telecommunication equipment rooms,transforms the original air-conditioning system of the existing communication equipment rooms in Beijing to save energy.Adds a set of natural cooling heat transfer system into the original single air-conditioning system,based on the theory and principle of natural cooling and heat exchange technology.Analyzes the operation situation for refrigeration condition in autumn 2009,the result shows that the proposed modification scheme not only can satisfy air distribution of the building and using function,but also has a significant energy-saving effect.
Keywords:telecommunication room  heat pipe exchanger  natural cooling technology  experimental research  engineering application  air-conditioning