40t/h循环流化床锅炉燃烧工况差的原因分析与改造
引用本文:申莉,张世红,刘德昌,刘昌明,周邦旭,刘道咏,黄绪勇. 40t/h循环流化床锅炉燃烧工况差的原因分析与改造[J]. 电站系统工程, 2002, 18(3): 13-15
作者姓名:申莉  张世红  刘德昌  刘昌明  周邦旭  刘道咏  黄绪勇
作者单位:1. 华中科技大学
2. 湖北大冶火力发电厂
摘    要:中小型循环流化床锅炉普遍存在燃烧效率较低、飞灰含碳量较高的现象。以人冶电厂两台40t/h CFB锅炉为例,分析了燃烧工况差的原因.并提出改进措施。实践证明这些改进措施是有效的。

关 键 词:循环流化床  燃烧工况  改进措施
文章编号:1005-006X(2002)03-0013-03
修稿时间:2001-09-30

Analysis and Improving Measures of 40t/h CFB Boiler Combustion Efficiency
SHEN Li,ZHANG Shi-hong,LIU De-chang,et al.. Analysis and Improving Measures of 40t/h CFB Boiler Combustion Efficiency[J]. Power System Engineering, 2002, 18(3): 13-15
Authors:SHEN Li  ZHANG Shi-hong  LIU De-chang  et al.
Abstract:For some medium sized and small sized industrial boilers, there is a common problem that thecombustion efficiency is low.The reasons for bad and unstable combustion in two 40t/h CFB boilers of DayePower Plant are analyzed. The improving measures are presented. It has been proved that some measures arevery effective.
Keywords:CFB  combustion conditions  improving measures