直管科氏力质量流量计的激振电路设计
引用本文:刘强,谭成武,何丽华,许治平.直管科氏力质量流量计的激振电路设计[J].辽宁石油化工大学学报,1995(4).
作者姓名:刘强  谭成武  何丽华  许治平
摘    要:科里奥利质量流量计的核心电路是机电一体化的激振电路(下简称激根电路)和时间差检测电路。激振电路设计的好坏关系到整个流量计的性能,诸如流量计的精度、稳定性、重复性和抗干扰能力以及提供易于后级电路处理的信号等.分析了直管科里奥利质量流量计的激振电路设计原则并给出了设计实例和经实验可行的电路.

关 键 词:科里奥利力  质量流量计  激励电路

Design of Excitational Circuit of Straight-Tube Coriolis Mass Flowmeter
Liu Qiang, Tan Chengwu, He Lihua, Xu Zhiping.Design of Excitational Circuit of Straight-Tube Coriolis Mass Flowmeter[J].Journal of Liaoning University of Petroleum & Chemical Technology,1995(4).
Authors:Liu Qiang  Tan Chengwu  He Lihua  Xu Zhiping
Affiliation:Department of Automation
Abstract:The core circuit of coriolis mass flowmeter are excitation circuit electronically and mechanically combined (briefly excitation circuit) and time difference measuring circuit. The performance quality of coriolis mass flowmeter, such as, precrsion, stability, repeatability immunity, primarily, depends on the design quality of excitation circuit, and the ability to provide signals easily processed by successive circuit. The design principle of excitation circuit is analysed, and the diagram of excitation circuit is provided which has been proved practical by experiments.
Keywords:Coriolis force  Mass flowmeter  Excitational circuit  