首页 | 本学科首页   官方微博 | 高级检索  
     


Building dampness and mold in European homes in relation to climate,building characteristics and socio‐economic status: The European Community Respiratory Health Survey ECRHS II
Authors:D Norbäck  J‐P Zock  E Plana  J Heinrich  C Tischer  R Jacobsen Bertelsen  J Sunyer  N Künzli  S Villani  M Olivieri  G Verlato  A Soon  V Schlünssen  M I Gunnbjörnsdottir  D Jarvis
Affiliation:1. Department of Medical Sciences, Uppsala University, Uppsala, Sweden;2. Centre for Research in Environmental Epidemiology (CREAL), Barcelona, Spain;3. Municipal Institute of Medical Research (IMIM‐Hospital del Mar), Barcelona, Spain;4. CIBER Epidemiologia y Salud Publica, (CIBERESP), Madrid, Spain;5. German Research Centre for Environmental Health, Institute of Epidemiology, Helmholtz Zentrum München, Neuherberg, Germany;6. Department of Occupational Medicine, Haukeland University Hospital, Bergen, Norway;7. Pompeu Fabra University, (UFP), Barcelona, Spain;8. Swiss Tropical and Public Health Institute (Swiss TPH), Basel, Switzerland;9. University of Basel, Basel, Switzerland;10. Department of Public Health, Experimental and Forensic Medicine, Unit of Biostatistics and Clinical Epidemiology, University of Pavia, Pavia, Italy;11. Occupational Medicine, University of Verona, Verona, Italy;12. Epidemiology and Medical Statistics, University of Verona, Verona, Italy;13. Department of Public Health, University of Tartu, Tartu, Estonia;14. Estonian Research Council, Tartu, Estonia;15. Department of Public health, Aarhus University, Aarhus, Denmark;16. The National Research Center for the Working Environment, Copenhagen, Denmark;17. Allergy Department, Landspitali University Hospital, Reykjavik, Iceland;18. Respiratory Epidemiology and Public Health Group, National Heart and Lung Institute, Imperial College, London, UK
Abstract:We studied dampness and mold in homes in relation to climate, building characteristics and socio‐economic status (SES) across Europe, for 7127 homes in 22 centers. A subsample of 3118 homes was inspected. Multilevel analysis was applied, including age, gender, center, SES, climate, and building factors. Self‐reported water damage (10%), damp spots (21%), and mold (16%) in past year were similar as observed data (19% dampness and 14% mold). Ambient temperature was associated with self‐reported water damage (OR=1.63 per 10°C; 95% CI 1.02‐2.63), damp spots (OR=2.95; 95% CI 1.98‐4.39), and mold (OR=2.28; 95% CI 1.04‐4.67). Precipitation was associated with water damage (OR=1.12 per 100 mm; 95% CI 1.02‐1.23) and damp spots (OR=1.11; 95% CI 1.02‐1.20). Ambient relative air humidity was not associated with indoor dampness and mold. Older buildings had more dampness and mold (P<.001). Manual workers reported less water damage (OR=0.69; 95% CI 0.53‐0.89) but more mold (OR=1.27; 95% CI 1.03‐1.55) as compared to managerial/professional workers. There were correlations between reported and observed data at center level (Spearman rho 0.61 for dampness and 0.73 for mold). In conclusion, high ambient temperature and precipitation and high building age can be risk factors for dampness and mold in homes in Europe.
Keywords:building characteristics  building dampness  climate  environment  indoor  mould  socio‐economic status
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号