一种新型UPS后备蓄电池组切换解决方案
引用本文:刘俊健,袁林波,刘西翠.一种新型UPS后备蓄电池组切换解决方案[J].电信工程技术与标准化,2012(11):17-20.
作者姓名:刘俊健  袁林波  刘西翠
作者单位:中国移动通信集团广东有限公司东莞分公司
摘    要:本文提出一种新型UPS后备蓄电池组切换的解决方案,在双机并联功率均分UPS系统中,当一台UPS输出故障时,两台UPS的后备蓄电池组自动同时为负载供电,从而实现了蓄电池组实际后备时长无缩减、并联操作无安全隐患的效果。

关 键 词:UPS  蓄电池  自动切换

Anovel switching solution of UPS backup battery
LIU Jun-jian,YUAN Lin-bo,LIU Xi-cui.Anovel switching solution of UPS backup battery[J].Telecom Engineering Technics and Standardization,2012(11):17-20.
Authors:LIU Jun-jian  YUAN Lin-bo  LIU Xi-cui
Affiliation:(China Mobile Group Guangdong Co.,Ltd.Dongguan Branch,Dongguan 523129,China)
Abstract:This article proposed a novel switching solution of UPS backup battery .When a UPS output fault, the two UPS backup batteries automatically load supply which can achieve the effect that battery backup time without reduction, parallel operation no security risks.
Keywords:UPS  battery  suto-switch