竖向钢筋套筒挤压连接的预制钢筋混凝土剪力墙抗震性能试验研究
引用本文:李宁波,钱稼茹,叶列平,刘时伟. 竖向钢筋套筒挤压连接的预制钢筋混凝土剪力墙抗震性能试验研究[J]. 建筑结构学报, 2016, 37(1): 31-40
作者姓名:李宁波  钱稼茹  叶列平  刘时伟
作者单位:1. 清华大学 土木工程安全与耐久教育部重点实验室, 北京 100084; 2. 中国中元国际工程有限公司, 北京 100089;;3. 内蒙古蒙西工程设计有限公司, 内蒙古呼和浩特 010000
摘    要:对4个剪跨比为2.11,竖向钢筋套筒挤压连接的预制钢筋混凝土剪力墙试件进行了拟静力试验。其中,3个试件为一字形截面剪力墙,轴压比分别为0.5、0.6和0.2;1个试件为T形截面剪力墙,轴压比为0.5。试验结果表明:剪力墙以压弯破坏为主,边缘构件竖向钢筋受拉屈服、墙底两端混凝土受压破坏;水平荷载 位移滞回曲线有一定程度捏拢;一字形截面剪力墙及T形截面剪力墙翼缘端受压时极限位移角不小于1/80,T形截面剪力墙腹板端受压时极限位移角为1/110;对于偏心受压承载力试验值与GB 50010-2010规范公式计算值之比,一字形截面剪力墙约为1.20,T形截面剪力墙翼缘端受压和腹板端受压时分别为1.04和1.11;套筒挤压连接能有效传递钢筋拉、压荷载作用。竖向钢筋套筒挤压连接的预制钢筋混凝土剪力墙的抗震性能满足现行规范的要求。

关 键 词:拟静力试验   竖向钢筋套筒挤压连接  抗震性能  预制钢筋混凝土剪力墙  

Tests on seismic behavior of precast RC shear walls with vertical rebar splicing by pressed sleeve
LI Ningbo,QIAN Jiaru,YE Lieping,LIU Shiwei. Tests on seismic behavior of precast RC shear walls with vertical rebar splicing by pressed sleeve[J]. Journal of Building Structures, 2016, 37(1): 31-40
Authors:LI Ningbo  QIAN Jiaru  YE Lieping  LIU Shiwei
Affiliation:1. Key Laboratory of Civil Engineering Safety and Durability of China Education Ministry,; Tsinghua University, Beijing 100084, China; 2. China IPPR International Engineering Co., Ltd, Beijing 100089, China;;3. Inner Mongolia Mengxi Engineering Design Co., Ltd, Hohhot 010000, China
Abstract:Quasi-static tests of four precast concrete shear wall specimens with shear span ratio of 2.11 were conducted. The vertical rebar of the precast shear wall was spliced by pressed sleeves. Among them, three shear walls had a rectangular section and the axial load ratios were 0.5, 0.6 and 0.2 respectively. One shear wall had a T section and an axial load ratio 0.5. The test results indicate that the shear wall specimens fail in compression and flexure interaction. The vertical rebars at boundary elements yield in tension and concrete at the edge of wall bottom crush in compression. The lateral force-displacement hysteretic loops have a degree of pinch. The ultimate rotation angles of the shear walls with rectangular section and T section, where the flange is in compression, are not less than 1/80. The ultimate rotation angle of shear wall with T section, where the web is in compression,is 1/110. The ratio of the measured compression-flexure strength to the calculated strength according to the formula of GB 50010-2010 is about 1.20 for the shear walls with rectangular section. The ratios become 1.04 and 1.11 for walls with T section, where the flange and web are in compression respectively. The pressed sleeve connector can transfer the tensile and compressive forces of rebar effectively. The seismic behavior of the precast shear wall with the vertical rebar splicing by pressed sleeve satisfies the current code requirements.
Keywords:quasi-static test   seismic behavior   vertical rebar splicing by pressed sleeve  precast RC shear wall  
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《建筑结构学报》浏览原始摘要信息
点击此处可从《建筑结构学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏