摘    要:为了满足急需,根据重水堆核电站的实际释放资料,参照国际GB6249-86对压水堆流出物中放射性核素释放的控制水平,并考虑到干什么山厂址多堆型、多机组的特点,对可适用于秦山三期重水堆核电站的3H排放量控制值提出了建议,并对通用控制值可能的取值范围进行了讨论.

关 键 词:重水堆    排放量控制值  建议
文章编号:0258-0918-(2003)03-0256-10
修稿时间:2003年4月7日

Control level recommendations for 3H discharge of PHWR
WANG Wen,hai.Control level recommendations for 3H discharge of PHWR[J].Chinese Journal of Nuclear Science and Engineering,2003,23(3):256-265.
Authors:WANG Wen  hai
Abstract:In order to meet the imperative necessity,a proposed control level of 3H discharge is offered which could be appropriate for Qinshan PHWR after getting approval from authority.The potential scope of general control value to PHWR in China is also evaluated.The work is based on the actual release of PHWRs and the release control levels of PWR regulated in the national standard GB 6249-1986,and the specificity of multiple reactor types and multiple units on Qinshan site was considerated.
Keywords:heavy water reactor  3H  discharge control level  recommendations