Treatment of cutout of a lag screw of a dynamic hip screw in an intertrochanteric fracture |
| |
Authors: | CC Wu CH Shih WJ Chen CL Tai |
| |
Affiliation: | Department of Orthopedics, Chang Gung Memorial Hospital, Taoyuan, Taiwan. |
| |
Abstract: | Sixteen consecutive patients with cutout of a lag screw of a dynamic hip screw fixation in an intertrochanteric fracture were treated with reinsertion of a lag screw, bone cement supplementation in the neck-trochanter, and subtrochanteric valgus osteotomy. Postoperatively, patients were permitted to ambulate with protected weight-bearing. Fourteen patients were followed-up for at least 1 year (median 2 years; range 1-3 years), and all had a solid union. The union period took a median of 5 months, with a range of 3-7 months. Usually, union of an intertrochanteric fracture was faster than that of subtrochanteric osteotomy (P < 0.01). There were no complications of wound infection, loss of reduction, cutout of a lag screw, or osteonecrosis of the femoral head. From clinical and theoretical considerations, we conclude that despite cutout of a lag screw of a dynamic hip screw fixation being difficult to treat, out technique still can provide an excellent outcome. Therefore, we strongly recommend its wide use. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|