首页 | 本学科首页   官方微博 | 高级检索  
     


Treatment of cutout of a lag screw of a dynamic hip screw in an intertrochanteric fracture
Authors:CC Wu  CH Shih  WJ Chen  CL Tai
Affiliation:Department of Orthopedics, Chang Gung Memorial Hospital, Taoyuan, Taiwan.
Abstract:Sixteen consecutive patients with cutout of a lag screw of a dynamic hip screw fixation in an intertrochanteric fracture were treated with reinsertion of a lag screw, bone cement supplementation in the neck-trochanter, and subtrochanteric valgus osteotomy. Postoperatively, patients were permitted to ambulate with protected weight-bearing. Fourteen patients were followed-up for at least 1 year (median 2 years; range 1-3 years), and all had a solid union. The union period took a median of 5 months, with a range of 3-7 months. Usually, union of an intertrochanteric fracture was faster than that of subtrochanteric osteotomy (P < 0.01). There were no complications of wound infection, loss of reduction, cutout of a lag screw, or osteonecrosis of the femoral head. From clinical and theoretical considerations, we conclude that despite cutout of a lag screw of a dynamic hip screw fixation being difficult to treat, out technique still can provide an excellent outcome. Therefore, we strongly recommend its wide use.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号