摘    要:通过对一种QJZ-400型矿用隔爆磁力启动器的结构、主要技术指标和工作原理的介绍,总结了可能发生的故障现象及其排查方法。

关 键 词:矿井  隔爆  磁力启动器  故障排查

Discussion on Troubleshooting to QJZ-400 Flameproof Magnetic Starter for Coal Mine
ZHANG Heng , LI Guan-ya , XUE Jian-dong.Discussion on Troubleshooting to QJZ-400 Flameproof Magnetic Starter for Coal Mine[J].Electric Explosion Protection,2012(4):30-33.
Authors:ZHANG Heng  LI Guan-ya  XUE Jian-dong
Affiliation:ZHANG Heng , LI Guan - ya, XUE Jian - dong ( 1. Mine of China Pingmei Shenma Group, Henan Pingdingshan 467045 ; Pingdingshan Institute of Industry Technology, Henan Pingdingshan 467001 )
Abstract:QJZ -400 flameproof magnetic starter ior coal mine is widely used. However, pro- tective circuits used for the same type of magnetic starters made by different manufacturer are different. it brough inconvenience to an electrician for maintaining or repairing underground. This article gives an outline of the structure and principle of QJZ -400 flameproof magnetic starters.