首页 | 本学科首页   官方微博 | 高级检索  
     

On-line Preconcentration of Trace Nickel from Electrolytic Manganese Using Minicolumn Packed Activated Carbon for Electrothermal Atomic Absorption Spectrometry
作者姓名:姚俊
作者单位:Jishou University
基金项目:FundedbytheScientificandTechnologicalProjectofTack leKeyProbleminScienceandTechnologyBranchofHunanProvince (No.0 0GKY2 0 2 0,0 1GKY2 0 2 7)andtheKeyProjectofHunanProvincialEducationalBranch(0 2A0 4 0 )
摘    要:1 IntroductionElectrolyticmanganeseisanimportantmetallurgicalproductthathasbeenregardedasakindofcombatreadi nessmaterialinseveralcountries1] .Itisamainindustri alexportproductofXiangxiAutonomousRegionofChina .However,theimpuritycontentintheelectrolyticm…

关 键 词:在线预富集    电热原子吸收光谱法  活性碳  电解锰
收稿时间:27 June 2003
修稿时间:18 October 2004

On-line preconcentration of trace nickel from electrolytic manganese using minicolumn packed activated carbon for electrothermal atomic absorption spectrometry
Yao?Jun,Krzysztof?Jankowski,Tuo?Yong,Yao?Zu-feng,Xiao?Yi,Xiao?Song-hua,Tan?Zhu-zhong.On-line Preconcentration of Trace Nickel from Electrolytic Manganese Using Minicolumn Packed Activated Carbon for Electrothermal Atomic Absorption Spectrometry[J].Journal of Wuhan University of Technology. Materials Science Edition,2004,19(4):17-20.
Authors:Yao Jun  Krzysztof Jankowski  Tuo Yong  Yao Zu-feng  Xiao Yi  Xiao Song-hua  Tan Zhu-zhong
Affiliation:(1) Warsaw University of Technology, Hunan, China;(2) Nanfang Manganese Group of Hunan, Hunan, China;(3) China University of Geosciences, China;(4) Present address: Department of Chemistry, College of Chemistry and Chemical Engineering, Jishou University, 416000 Jishou, China
Abstract:The online flow injection preconcentration and electrothermal atomic absorption spectrometry method were used for the determination of trace nickel in electrolytic manganese samples by sorption on a conical minicolumn packed with activated carbon at pH 9.0. The nickel was eluted from the minicolumn with 10% (v/v) nitric acid. An enrichment factor of 190-fold for a sample volume of 10mL was obtained. The detection limit (DL) of nickel with the use of the preconcentration method was 13ng·g−1 in the original solid sample. The precision for 10 replicate determinations at 150ng·g−1 nickel concentration was 5.2% relative standard deviation (RSD). The calibration graph was linear with a correlation coefficient of r=0.9996 up to concentration of 660ng·g−1 nickel. YAO Jun Funded by the Scientific and Technological Project of Tackle Key Problem in Science and Technology Branch of Hunan Province (No. 00GKY2020; 01GKY2027) and the Key Project of Hunan Provincial Educational Branch (02A040)
Keywords:online preconcentration  nickel  electrothermal atomic absorption spectrometry  activated carbon  electrolytic manganese
本文献已被 CNKI 万方数据 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号