首页 | 本学科首页   官方微博 | 高级检索  
     

施工误差对剪力钉工作性能的影响
引用本文:封博文,刘永健,彭元诚,孙立鹏,刘江,张凯. 施工误差对剪力钉工作性能的影响[J]. 建筑科学与工程学报, 2018, 0(1): 119-126
作者姓名:封博文  刘永健  彭元诚  孙立鹏  刘江  张凯
作者单位:长安大学公路学院
摘    要:为了研究施工误差对剪力钉工作性能的影响,通过3个无误差剪力钉推出试验,探究剪力钉抗剪力学性能,并根据试验结果验证有限元模拟方法的准确性。在此基础上,考虑施工过程中可能发生的混凝土浇筑不密实、剪力钉布置边距不足、剪力钉倾斜3种施工误差,通过有限元模拟计算分析得到在各施工误差影响下剪力钉抗剪承载力及破坏模式。结果表明:无误差试件剪力钉破坏模式均为剪力钉根部剪断破坏,抗剪承载力试验值均大于各规范计算值;有限元分析得到剪力钉附近混凝土浇筑不密实可使剪力钉抗剪承载力降低60%~70%;剪力钉至混凝土边缘距离不满足规范要求可使剪力钉抗剪承载力降低27%;剪力钉倾斜可使剪力钉抗剪承载力降低41%;混凝土浇筑不密实对剪力钉抗剪承载能力影响最大。

关 键 词:桥梁工程  剪力钉  施工误差  推出试验  抗剪承载力

Influence of Construction Error on Working Performance of Shear Stud
FENG Bo-wen,LIU Yong-jian,PENG Yuan-cheng,SUN Li-peng,LIU Jiang,ZHANG Kai. Influence of Construction Error on Working Performance of Shear Stud[J]. Journal of Architecture and Civil Engineering, 2018, 0(1): 119-126
Authors:FENG Bo-wen  LIU Yong-jian  PENG Yuan-cheng  SUN Li-peng  LIU Jiang  ZHANG Kai
Affiliation:School of Highway, Chang’an University
Abstract:In order to study the influence of construction error on working performance of shear studs, through push-out test on three shear stud specimens without error to explore the shear mechanical properties of shear stud, meanwhile, according to the test results, the accuracy of the finite element method was proved. On this basic, considering the non-compactness concrete pouring, insufficient margin of shear stud layout and incline of shear stud in process of construction, and through the finite element simulation and analysis, shear capacity and failure modes of the shear stud under construction error were gained. The results indicate that the failure modes of shear studs without error are all shear failure in the shear stud root, the test values of shear capacity are greater than the calculated values of specifications. The finite element analysis results show that non-compactness concrete pouring near shear stud decreases shear bearing capacity by 60%-70%, insufficient margin of shear stud layout without meeting specifications decreases shear bearing capacity by 27%, and incline of shear stud decreases shear bearing capacity by 41%. The non-compactness concrete pouring is the greatest influence on the shear capacity of shear stud.
Keywords:bridge engineering  shear stud  construction error  push-out test  shear bearing capacity
本文献已被 CNKI 等数据库收录!
点击此处可从《建筑科学与工程学报》浏览原始摘要信息
点击此处可从《建筑科学与工程学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏