首页 | 本学科首页   官方微博 | 高级检索  
     


Web crippling strength of a steel sandwich panel with V-shaped webs
Authors:Taichiro Okazaki  Brian J Siljenberg  Carol K Shield  Susan C Mantell
Affiliation:1. Department of Civil Engineering, University of Minnesota, Minneapolis, MN 55455, USA;2. Structural Engineer, HGA Architects and Engineers, Minneapolis, MN 55401, USA;3. Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN 55455, USA
Abstract:Steel sandwich panels with V-shaped web flutes (V-core panels) serve the structural functions of a proposed energy-efficient roof system for residential construction. Due to its intended use as a flexural member spanning between a ridge beam and a structural wall, and required slender webs for weight considerations, web crippling under end one-flange loading is a critical strength limit state for the V-core panels. Although the 2001 North American Specification for the Design of Cold-Formed Steel Structural Members provides a design procedure to address web crippling, those design rules were developed for members whose cross sections are different from that of V-core panels. Consequently, nine specimens were tested to collect data on V-core panels subjected to end one-flange loading. Test observations suggested that V-core panels behave very similarly to multi-web decks that are strapped and unfastened to the supports. Experimental data reported in the literature was used to modify the web crippling strength equation in the Specification to reflect these particular conditions. The modified equation was found to adequately predict the measured web crippling strength of V-core panels.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号